RS 06

RS Para # Wrong

Indramat · ServoDyn D Servo Drive

¿Qué significa RS 06 ?

This serial communication error indicates that the parameter number transmitted to the CLM01.3-M is invalid. The parameter number must be provided in a two-digit format and fall within the range of 00 to 99.

Causas comunes

  • The parameter number in the serial command is outside the valid two-digit range (00-99).
  • Typographical error in the parameter number within the transmitted serial command (e.g., a single digit, or an extra digit).
  • Corrupted data transmission over the serial interface.
  • Sending device software bug generating incorrect parameter numbers.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify that the parameter number being transmitted is a two-digit number between 00 and 99. Refer to Chapter 7 (Serial Interface) for the correct parameter format.

  2. 2

    Correct the parameter number in the transmitted serial command to adhere to the specified format and range.

  3. 3

    Check the serial communication link for noise, interference, or incorrect cabling that could corrupt data.

  4. 4

    Re-transmit the parameter command after verifying the parameter number and overall command format.

  5. 5

    Ensure the sending device's software generates parameter numbers correctly according to the CLM01.3-M specifications.