Traduciendo...
F7011

Safety rel. position limit val., exc. in pos. dir.

Indramat · Indradrive

¿Qué significa F7011 ?

The motor's actual position has exceeded a defined safety-related position limit in the positive direction. This fault is triggered by safety monitoring functions (e.g., Safely Limited Position) to prevent the axis from moving beyond a safe physical boundary.

Causas comunes

  • Uncontrolled or unintended movement beyond the positive safety limit.
  • Incorrectly configured safety-related positive position limit parameter.
  • Faulty position feedback (encoder) providing erroneous actual position values.
  • Mechanical overrun due to excessive inertia or braking distance.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the configured safety-related positive position limit parameter (e.g., S-0-0XXX Safe Positive Position Limit) in the IndraDrive.

  2. 2

    Check for any mechanical issues that could cause the axis to overshoot its intended position, such as worn brakes or excessive play.

  3. 3

    Inspect the position encoder and its cabling for proper function and signal integrity.

  4. 4

    Review the motion control program for unintended commands or logic errors that might cause overtravel.

  5. 5

    Adjust deceleration ramps or braking parameters if the axis consistently overshoots due to inertia.

Ver todos los códigos en este manual (60)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas