Current Limitation Active
Indramat · ECODRIVE Controller
¿Qué significa E260 ?
This warning indicates that the ECODRIVE DKC01.1/DKC11.1 speed controller is entering its limit, meaning the acceleration capacity of the drive has been exceeded. In position control mode, this results in an ever-increasing deviation between command and actual values (lag error).
Causas comunes
- Parametrized acceleration value is too high for the drive's capacity or connected load.
- Speed value is set too high in position control mode for the application dynamics.
- Torque limit value in the ECODRIVE DKC01.1/DKC11.1 drive is set too low.
- Excessive load or friction on the mechanical system.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
In position control mode, reduce the parametrized acceleration value or speed value to allow the ECODRIVE DKC01.1/DKC11.1 drive to follow the position command.
- 2
Increase the torque limit value in the drive parameters if necessary and permissible by the application and motor ratings.
- 3
Inspect the mechanical system for excessive load, binding, or friction that could be hindering motion.
- 4
Verify motor sizing against the application requirements to ensure it can deliver the necessary torque.