Bleeder Overtemperature Warning
Indramat · ECODRIVE Controller
¿Qué significa E252 ?
The internal or external braking resistor (bleeder) has reached a high operating temperature, nearing its maximum permissible limit. This warning indicates that continuous operation under these conditions may lead to an F220 shutdown of the ECODRIVE DKC01.1/DKC11.1 drive.
Causas comunes
- Excessive regenerative energy due to frequent or rapid decelerations, or heavy overhauling loads.
- Improperly sized or faulty external braking resistor.
- Inefficient cooling or poor ventilation for the braking resistor.
- Overloading of the drive's internal bleeder circuit.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the duty cycle and deceleration rates of the application; consider extending deceleration times or reducing frequency.
- 2
Inspect the external braking resistor for signs of overheating, proper connection, and verify its ohmic value.
- 3
Ensure adequate airflow and ventilation around the braking resistor and within the control cabinet.
- 4
Evaluate if the braking resistor is appropriately sized for the regenerative energy profile of the application.
- 5
Monitor the DC bus voltage during braking events and the temperature of the bleeder if possible.