F406

Phase switching without ready signal

Indramat · CLM01.3-M Flying Cutoff Control

¿Qué significa F406 ?

The SERCOS master attempted a phase switch without waiting for the drive controller’s ready signal, indicating an error in the SERCOS master module of the control system.

Causas comunes

  • Error in the SERCOS master module of the control system.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Review the SERCOS master controller's diagnostic messages and event logs for further details regarding the premature phase switch attempt.

  2. 2

    Verify the SERCOS communication parameters and timing settings in the master controller to ensure they align with the requirements of the Indramat DIAX04 SSE-03VRS drive controllers.

  3. 3

    Check the firmware version of the SERCOS master module for any known issues or required updates.

  4. 4

    Monitor the ready signal status from the Indramat DIAX04 SSE-03VRS drive controllers to confirm they are indeed reporting their ready state correctly.

  5. 5

    If the problem persists and appears to originate from the master controller's logic or hardware, consult the control system manufacturer for advanced diagnostics or potential module replacement.