F405

Error during phase regression

Indramat · CLM01.3-M Flying Cutoff Control

¿Qué significa F405 ?

Switching back from a communication phase did not result in a switch to phase 0, indicating a malfunction in the SERCOS master module of the controller connected to the Indramat DIAX04 SSE-03VRS drive.

Causas comunes

  • Malfunction in the SERCOS master module of the controller.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the SERCOS communication configuration parameters in the master controller for any incorrect or conflicting settings.

  2. 2

    Check the status and diagnostic LEDs on the SERCOS master module for specific error indications that might point to its internal state.

  3. 3

    Ensure the master controller's firmware is up-to-date and compatible with the Indramat DIAX04 SSE-03VRS drive controllers.

  4. 4

    If possible, attempt to reinitialize the SERCOS communication ring from the master controller's interface.

  5. 5

    If the issue persists, the SERCOS master module itself may be defective and require further investigation or replacement by the control system manufacturer.

Ver todos los códigos en este manual (31)