Positive travel limit exceeded
Indramat · DIAX 04
¿Qué significa F629 ?
The DIAX04 SSE-03VRS drive has detected that the machine axis has moved beyond its configured positive software travel limit. This is a safety and machine protection fault, indicating that the axis is outside its allowed operating range, potentially risking mechanical damage or collision. The drive attempts to stop motion safely.
Causas comunes
- Incorrectly configured positive software travel limit (e.g., S-0-0049) in the DIAX04 SSE-03VRS drive.
- Commanded position exceeded the positive software limit due to an error in the motion profile or control program.
- Faulty position feedback (encoder) providing incorrect position data, making the drive miscalculate its actual position.
- Mechanical system failure or excessive inertia causing overshoot beyond the commanded limit.
- Ignoring or overriding limit switch signals incorrectly.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Manually move the machine axis back into the allowed travel range, ensuring no mechanical obstructions.
- 2
Verify and adjust the positive software travel limit parameter (e.g., S-0-0049) in the DIAX04 SSE-03VRS drive to match the actual mechanical limits.
- 3
Review the motion program or commands to ensure no position setpoints exceed the defined limits.
- 4
Inspect the motor encoder and its wiring for proper function and accurate position feedback.
- 5
Check the physical positive limit switch for functionality and correct activation, ensuring it is not bypassed or faulty.