F507

Safety input signals wrong, checksum

Indramat · DIAX 04

¿Qué significa F507 ?

The DIAX04 SSE-03VRS drive's safety module detected a checksum error in the received safety input signals. This means the integrity of the safety-related data transmitted from an external safety device (e.g., safety PLC) or across internal channels is compromised. This is a critical safety fault, as the drive cannot trust the received safety commands.

Causas comunes

  • Corrupted safety data telegram due to electromagnetic interference on the safety communication link.
  • Faulty external safety PLC or safety communication module transmitting incorrect checksums.
  • Damage or poor shielding on the safety communication cable to the DIAX04 SSE-03VRS drive.
  • Internal fault within the DIAX04 SSE-03VRS drive's safety module that calculates or checks checksums.
  • Mismatched safety communication protocols or versions between the external device and the DIAX04 SSE-03VRS.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the safety communication link (e.g., Profisafe, F-Link) cabling for damage, proper shielding, and termination.

  2. 2

    Verify the status and diagnostic logs of the external safety PLC or safety communication module for any errors.

  3. 3

    Ensure that the safety communication protocol and configuration parameters are identical and compatible between the external safety device and the DIAX04 SSE-03VRS drive.

  4. 4

    Check for sources of excessive electromagnetic interference near the safety communication cables.

  5. 5

    Perform a full power cycle of the DIAX04 SSE-03VRS system and the external safety device. If the fault persists, consider a faulty safety communication interface on the drive.

Ver todos los códigos en este manual (60)