Double MST failure shutdown
Indramat · DIAX 04
¿Qué significa F401 ?
The DIAX04 SSE-03VRS drive detected a double failure of the Master Synchronization Telegram (MST) within its real-time communication network (e.g., Sercos). This means the drive has lost synchronization with the master controller twice consecutively. This is a critical communication fault that results in immediate shutdown to prevent uncoordinated and potentially dangerous movements.
Causas comunes
- Repeated interruptions or severe degradation of the real-time communication link (e.g., fiber optic cable, Sercos ring) to the DIAX04 SSE-03VRS drive.
- Master controller experiencing issues generating or transmitting the MST.
- Faulty communication interface or hardware on the DIAX04 SSE-03VRS drive.
- Incorrect network configuration or timing parameters (e.g., S-0-0010) causing synchronization loss.
- Excessive electromagnetic interference impacting communication signal integrity.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Inspect the communication cable (e.g., fiber optic, Ethernet) connecting the DIAX04 SSE-03VRS drive to the master controller. Check for physical damage, proper termination, and secure connections.
- 2
Verify the status of the master controller's communication interface and its ability to transmit MSTs.
- 3
Check communication ring integrity (if applicable) for breaks or faulty nodes. Bypass or isolate sections to identify the problematic segment.
- 4
Review and verify communication parameters (e.g., S-0-0010, S-0-0011) in the DIAX04 SSE-03VRS drive and the master controller for consistency.
- 5
Monitor communication diagnostic indicators on both the master and the DIAX04 SSE-03VRS. If the fault persists, consider a faulty communication interface on the drive.