Traduciendo...
F318

Heatsink overtemp. fault power supply unit

Indramat · DIAX 04

¿Qué significa F318 ?

The DIAX04 SSE-03VRS power supply unit's internal heatsink temperature has exceeded its maximum safe operating limit, resulting in a shutdown. This protects the power components from thermal damage. It typically signifies insufficient cooling or sustained overloading of the power supply unit.

Causas comunes

  • Ambient temperature in the control cabinet is too high for the DIAX04 SSE-03VRS power supply unit.
  • Cooling fan on the power supply unit is blocked, dirty, or faulty.
  • Heat sink fins of the power supply unit are clogged with dust or debris, impairing heat dissipation.
  • The DIAX04 SSE-03VRS power supply unit is overloaded, drawing continuous current beyond its rating.
  • Insufficient ventilation or mounting clearances for the power supply unit in the control cabinet.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Allow the DIAX04 SSE-03VRS power supply unit to cool down completely before attempting a reset.

  2. 2

    Inspect the cooling fan on the power supply unit for proper operation, obstructions, and cleanliness.

  3. 3

    Clean any dust or debris from the heat sink fins of the DIAX04 SSE-03VRS power supply unit.

  4. 4

    Verify the ambient temperature in the control cabinet is within the specified operating range.

  5. 5

    Check the load on the power supply unit and ensure it is not continuously exceeding its rated capacity. Reduce load or consider a larger power supply.

Ver todos los códigos en este manual (60)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas