Low battery voltage
Indramat · DIAX 04
¿Qué significa F248 ?
The DIAX04 SSE-03VRS drive has detected that the internal battery, which often maintains encoder absolute position data or retains parameters during power-off, has a critically low voltage. This condition risks losing critical configuration data or absolute position references upon power loss. It requires immediate attention to prevent data loss.
Causas comunes
- The internal battery on the DIAX04 SSE-03VRS or an attached encoder is discharged or has reached the end of its service life.
- Poor contact or connection to the battery terminals.
- Charging circuit for the battery (if rechargeable) is faulty.
- Prolonged power-off periods without external power, draining the battery.
- Incorrect battery type or specification installed.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Locate the battery on the DIAX04 SSE-03VRS drive or the associated absolute encoder. Measure its voltage with a multimeter.
- 2
Replace the battery with a new, compatible battery of the correct type and specification.
- 3
Verify the battery connections are clean, tight, and correctly polarized.
- 4
If the battery is rechargeable, check the charging circuit functionality by measuring voltage at the battery terminals with the drive powered on.
- 5
After replacing the battery, re-home or re-reference any absolute encoders to restore their position data.