Traduciendo...
String Current Backfeed

String Current Backfeed

Huawei · SUN2000 Series Solar Inverter

¿Qué significa String Current Backfeed ?

The DC SWITCH has automatically turned off, signaling an event where current is flowing back into the PV strings from the inverter or another source. This condition can indicate an internal fault within the inverter or an external wiring issue that could damage the PV array or the SUN2000 inverter.

Causas comunes

  • Internal fault within the inverter allowing current to backfeed into PV strings.
  • External electrical fault or short circuit on the DC side causing reverse current flow.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Identify and rectify the cause of current backfeed into the PV strings.

  2. 2

    After rectification, wait for at least 3 minutes.

  3. 3

    Set the DC SWITCH handle to OFF to complete the reset procedure.

  4. 4

    Set the DC SWITCH handle to ON to restart the inverter.

Ver todos los códigos en este manual (4)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Huawei SUN2000 Series Solar Inverter