107
String 2 Abnormal
Huawei · SUN2000 8-28KTL Solar Inverter
¿Qué significa 107 ?
A warning indicating that PV string 2 is performing abnormally, possibly due to long-term shielding or deterioration. This results in reduced power output from the specific string, decreasing overall system efficiency.
Causas comunes
- PV string 2 has been shielded for a long time.
- PV string 2 has deteriorated.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check whether the output current of PV string 2 is significantly less than the output current of other PV strings.
- 2
If current is low, check whether PV string 2 is shielded by contaminants or obstructions.
- 3
If PV string 2 is clean and not shielded, check individual PV modules within string 2 for faults.