2039
Output overcurrent
Huawei · SUN2000-(3KTL-10KTL)-M1 Solar Inverter
¿Qué significa 2039 ?
The SUN2000's transient output current exceeds its upper threshold, triggering protection due to a dramatic drop in power grid voltage or a short-circuited power grid. This indicates an external electrical fault affecting the inverter's output.
Causas comunes
- The power grid voltage drops dramatically.
- The power grid is short-circuited.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Observe if the SUN2000 automatically recovers after the fault is rectified, as it monitors external operating conditions in real time.
- 2
If the alarm persists and affects energy yield, check whether the output is short-circuited.