PSM/PSMR Input Power Supply Open Phase

Fanuc · Series 30i CNC

¿Qué significa E ?

This alarm signifies an abnormal input power supply condition, specifically an open phase in the incoming AC power to the Power Supply Module (PSM) or Power Supply Module with Regenerative (PSMR). An open phase means one or more phases of the three-phase input voltage are missing, which can prevent the module from operating or lead to unbalanced operation.

Causas comunes

  • The input power supply has an open phase condition (e.g., blown fuse, disconnected wire).

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the power supply voltage for all input phases at the PSM/PSMR terminals.

  2. 2

    If the power supply voltage is normal, check the physical connections of the input power supply wiring for disconnections or loose terminals.