U
Inverter: FSSB communication error (COP10B)
Fanuc · Series 30i/31i/32i-MODEL B Plus
¿Qué significa U ?
A FSSB (FANUC Serial Servo Bus) communication error has occurred, specifically involving the COP10B connection. This type of error is typically caused by a failure in the COP10B connector or cable, an issue with the Servo Amplifier, or a failure in the CNC unit. Loss of FSSB communication can halt machine operation.
Causas comunes
- Connector or cable (COP10B) failure
- Servo Amplifier failure
- CNC failure
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the integrity and secure connection of the COP10B connector and cable.
- 2
If the COP10B cable is confirmed good, replace the Servo Amplifier.
- 3
If the Servo Amplifier is confirmed good, replace the CNC unit.