386

DATA TRANS. ERROR(EXT)

Fanuc · Series 30i/31i/32i-MODEL B Plus

¿Qué significa 386 ?

This external alarm signals a communication data error from the separate detector, primarily caused by noise. Unstable position data from the separate detector can lead to erratic or inaccurate control.

Causas comunes

  • Noise causing unstable position data from the separate detector.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check CNC diagnosis information No.356 (Built-in detector) and No.357 (Separate detector) for incremented values, which indicate noise effects. The value is cleared when the CNC unit is powered off.