368
SERIAL DATA ERROR(INT)
Fanuc · Series 30i/31i/32i-MODEL B Plus
¿Qué significa 368 ?
This internal alarm indicates an interruption in serial communication, possibly due to a disconnected cable, a Pulse coder failure, or electrical noise. Loss of serial data communication prevents the control unit from receiving vital feedback information.
Causas comunes
- Communication interruption with the Pulse coder
- Cable disconnection in the feedback loop
- Pulse coder failure
- Noise interfering with serial data transmission
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check whether the feedback cable is not disconnected and whether the connector is properly plugged.
- 2
Replace the Pulsecoder.