DS0080

ILLEGAL COMMAND IN FLEXIBLE PATH AXIS ASSIGNMENT

Fanuc · Series 0i-MODEL F Plus Parameter

¿Qué significa DS0080 ?

This alarm occurs during flexible path axis assignment in direct assign mode if an axis removal command fails to execute. This specific behavior is enabled when parameter 11563 bit #3 (WUA) is set to 0, which prevents the system from waiting for the axis removal operation to complete.

Causas comunes

  • An invalid or unrecognized command has been issued within the 'Flexible Path Axis Assignment' configuration.
  • The control system encountered a command that is not supported for dynamically assigning axes in its flexible path architecture.
  • The PLC or a custom macro has generated a command that is syntactically incorrect or outside the allowed set for flexible path operations.
  • A specific configuration parameter (e.g., in P8-XX range) related to flexible path command interpretation is misconfigured.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check parameter 11563 bit #3 (WUA). If it is set to 0, the system will not wait for axis removal execution, leading to this alarm if the command cannot be immediately completed.

  2. 2

    If it is acceptable for the system to wait for axis removal, set parameter 11563 bit #3 (WUA) to 1 to potentially prevent this alarm.

  3. 3

    Investigate the specific conditions or state of the axis that prevented the removal command from executing successfully in flexible path axis assignment direct assign mode.