Resistor Module Abnormal Discharge (2) (ECM)
Fanuc · Macro B CNC Programming
¿Qué significa H ?
The Energy Charge Module's (ECM) Capacitor Modules are discharged due to a malfunction of the discharge circuit, rather than a commanded discharge. This indicates an uncontrolled or premature release of stored energy, suggesting a more severe failure within the discharge control mechanism or the Resistor Module itself.
Causas comunes
- Second detected instance of abnormal discharge by the resistor module (ECM).
- Resistor module (ECM) internal short circuit or open circuit.
- Inadequate discharge path for the resistor module (ECM).
- Control logic error for the resistor discharge function.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Immediately stop the machine using the emergency stop button and open the external Main Circuit Contactor (MCC) of the Power supply.
- 2
Inspect the Resistor Module (A06B-6158-H030) and its internal thermostat for proper operation and signs of damage or short circuit.
- 3
Check the control signals from the ECM Control Module (A06B-6158-H010) to the discharge circuit for any erroneous commands causing unintended discharge.
- 4
Verify the integrity of the discharge circuit components for any short circuits or component failures that could cause premature discharge.
- 5
Measure the resistance of the Resistor Module (expected 30 ohm, page 578) to ensure it is within specification.