Traduciendo...
C

Alarm of Power Supply (ECM)

Fanuc · Macro B CNC Programming

¿Qué significa C ?

A general alarm condition has occurred within the power supply unit of the Energy Charge Module (ECM). This indicates a problem with the main power input to the ECM or its internal power conversion circuitry.

Causas comunes

  • Power supply unit (ECM) internal fault or failure.
  • Overcurrent condition detected in the ECM power stage.
  • Short circuit in the connected load to the ECM.
  • Voltage instability from the main power source affecting ECM.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Immediately stop the machine using the emergency stop button and open the external Main Circuit Contactor (MCC) of the Power supply.

  2. 2

    Check the incoming main power supply voltage and frequency to the αi PS or power supply module; ensure it is within the specified range (e.g., 200-240 VAC for 200V series, 400-480 VAC for 400V series).

  3. 3

    Inspect the circuit breakers and magnetic contactors connected to the power supply for tripping or damage (Section 3.1.3.10, page 95).

  4. 4

    Verify that the power supply wiring (Cable K1, Section 9.3.1.1, page 213) is securely connected and has the correct cross-sectional area.

  5. 5

    If an external power transformer is used, check its input and output voltages for correctness and stability (Section 3.1.3.7, page 89).

Ver todos los códigos en este manual (26)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas