SV0484
SAFETY FUNCTION ERROR (SV)
Fanuc · Alpha i Series Servo Amplifier
¿Qué significa SV0484 ?
An error occurred in the servo's safety functions. This can be due to inexecution of servo software safety functions, a mismatch between servo software and CNC results for safety functions, or an error in a servo CPU or RAM test, indicating a critical safety system failure.
Causas comunes
- Safety function logic has detected a conflict or malfunction.
- Safety PLC input signal mismatch or failure.
- Incorrect configuration of safety I/O modules.
- Overlapping or incompatible safety zones detected.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
If the cause is related to inexecution of servo software safety functions (condition 1), a servo CPU test error (condition 3), or a servo RAM test error (condition 4), replace the axis control card.
Datos técnicos verificados. Última actualización: March 2026