Traduciendo...
SV0383

PULSE MISS(EXT)

Fanuc · Alpha i Series Servo Amplifier

¿Qué significa SV0383 ?

A pulse error occurred on the separate detector, indicating that expected pulses were not detected. This impacts the accuracy of position feedback from the external detector.

Causas comunes

  • Electrical noise or interference on the external detector's pulse signal lines.
  • Damage or slippage on the external detector's encoder disk.
  • Faulty pulse generation circuitry within the external detector.
  • External noise affecting the integrity of the pulse signal.
  • Incorrect pulse output configuration in servo parameters.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Measure signal amplitude on external detector output terminals.

  2. 2

    Inspect external detector encoder disk for scratches or misalignment.

  3. 3

    Test external detector signal generation with diagnostic tools.

  4. 4

    Install noise filters on power supply lines to the external detector.

  5. 5

    Verify parameter P1-01 (Encoder Pulse Output) setting.

Ver todos los códigos en este manual (101)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Fanuc Alpha i Series Servo Amplifier