Traduciendo...
SV0363

ABNORMAL CLOCK(INT)

Fanuc · Alpha i Series Servo Amplifier

¿Qué significa SV0363 ?

A clock alarm occurred on the built-in Pulsecoder. This points to a problem with the internal clock or timing synchronization of the Pulsecoder.

Causas comunes

  • Internal clock signal within the Pulsecoder is unstable or incorrect.
  • Damage to Pulsecoder's timing components.
  • Power supply fluctuations affecting the internal clock.
  • Environmental factors (temperature, vibration) impacting clock accuracy.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Measure voltage supply to the Pulsecoder.

  2. 2

    Check Pulsecoder for signs of overheating.

  3. 3

    Inspect Pulsecoder for physical damage to internal clock circuitry.

  4. 4

    Perform a diagnostic test on the Pulsecoder if available.

Ver todos los códigos en este manual (101)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Fanuc Alpha i Series Servo Amplifier