SV0362

ABNORMAL REV. DATA(INT)

Fanuc · Alpha i Series Servo Amplifier

¿Qué significa SV0362 ?

A speed count abnormal alarm occurred on the built-in Pulsecoder. This indicates an issue with the revolution count data or speed detection from the Pulsecoder.

Causas comunes

  • Pulsecoder is not accurately counting revolutions.
  • Internal speed detection circuitry is malfunctioning.
  • Mechanical issues affecting Pulsecoder's rotational reading.
  • Data transmission error of revolution counts.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Manually rotate the encoder and observe speed feedback on the CNC.

  2. 2

    Inspect Pulsecoder shaft and mounting for any play or binding.

  3. 3

    Check Pulsecoder's output signals for consistency.

  4. 4

    Verify Pulsecoder's internal resolution settings.

Ver todos los códigos en este manual (101)