SV0306

APC ALARM: OVER FLOW ERROR

Fanuc · Alpha i Series Servo Amplifier

¿Qué significa SV0306 ?

The amount of positional deviation overflowed, making it impossible to obtain the correct machine position. This indicates an issue with position monitoring.

Causas comunes

  • Large deviation between commanded and actual position.
  • Encoder resolution is insufficient for the commanded movement.
  • Mechanical backlash in the drive system exceeding limits.
  • CNC's internal position accumulator has overflowed.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Measure actual positional feedback from APC and compare to commanded position.

  2. 2

    Inspect drive train for excessive backlash.

  3. 3

    Ensure APC encoder resolution is appropriate for the application.

  4. 4

    Check CNC system limits for position accumulator size.

Ver todos los códigos en este manual (101)