SV0303
APC ALARM: FRAMING ERROR
Fanuc · Alpha i Series Servo Amplifier
¿Qué significa SV0303 ?
A framing error occurred in the data transfer from the absolute-position detector, preventing the system from obtaining the correct machine position. This problem is indicative of a defect in the absolute-position detector, its cable, or the servo interface module.
Causas comunes
- Incorrect data framing from the APC encoder.
- Data bit corruption during transmission.
- Faulty APC encoder sending malformed data packets.
- Interference on communication lines causing bit errors.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Inspect APC encoder output for framing errors using an oscilloscope.
- 2
Ensure correct data format (e.g., start bits, stop bits) is configured.
- 3
Test APC encoder signal integrity for noise or distortion.
- 4
Check APC encoder firmware for updates.