SV0302

APC ALARM: OVER TIME ERROR

Fanuc · Alpha i Series Servo Amplifier

¿Qué significa SV0302 ?

The absolute-position detector caused an overtime error during data transfer, meaning the correct machine position could not be obtained. This fault suggests a defect in the absolute-position detector, its cable, or the servo interface module.

Causas comunes

  • Slow response from the APC encoder during position updates.
  • Communication link is experiencing high latency or delays.
  • Overload on the APC processing unit.
  • Incorrect timing parameters set in CNC.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check for excessive system load on the CNC control.

  2. 2

    Measure communication line resistance and capacitance.

  3. 3

    Verify APC encoder's internal clock and communication speed.

  4. 4

    Adjust CNC communication timing parameters if applicable.

Ver todos los códigos en este manual (101)