Traduciendo...
10053
Linear Motor Scale Reverse Connection Bit Set Error
Fanuc · Alpha i Series Servo Amplifier
¿Qué significa 10053 ?
This invalid parameter setting alarm occurs when a linear motor is used, and the scale reverse connection bit (parameter 1960#0 for Series 15 or 2018#0 for Series 16, etc.) is set. This specific bit is not applicable and cannot be used with linear motors.
Causas comunes
- The linear motor's scale is connected in reverse orientation.
- The scale signal polarity is incorrect for the linear motor's operation.
- Parameter P102.2 (Scale Direction) is set to the wrong value.
- The linear motor scale sensor is installed backwards.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Clear the scale reverse connection bit (parameter 1960#0 or 2018#0) when operating with a linear motor.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Fanuc Alpha i Series Servo Amplifier