Traduciendo...
0886

Machine Velocity Feedback Coefficient Overflow

Fanuc · Alpha i Series Servo Amplifier

¿Qué significa 0886 ?

This invalid parameter setting alarm indicates that the internal calculation value of the machine velocity feedback coefficient has overflowed. This usually happens if the coefficient is set too high, exceeding internal processing limits.

Causas comunes

  • The calculated machine velocity feedback coefficient is too high.
  • A sensor reading related to machine speed has overflowed during coefficient calculation.
  • Parameter P601.2 (Velocity Feedback Coefficient) is set too high.
  • An internal process overflowed during the calculation of the velocity feedback gain.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Decrease the machine velocity feedback coefficient.

  2. 2

    Alternatively, utilize the vibration-damping control function, which offers an equivalent effect.

Ver todos los códigos en este manual (101)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Fanuc Alpha i Series Servo Amplifier