Traduciendo...
0545

Dead Zone Compensation Parameter Overflow

Fanuc · Alpha i Series Servo Amplifier

¿Qué significa 0545 ?

This invalid parameter setting alarm indicates that the internal calculation value of a parameter related to dead zone compensation has overflowed. This typically happens when the compensation setting is too high, leading to mathematical limits being exceeded.

Causas comunes

  • Dead zone compensation parameter calculation has overflowed.
  • Unstable compensation for mechanical dead zones.
  • Incorrect settings for dead zone compensation parameters (P04-12).
  • Mechanical play impacting control accuracy.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Decrease the setting of the parameter related to dead zone compensation to the extent that the invalid parameter setting alarm is no longer caused.

Ver todos los códigos en este manual (101)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Fanuc Alpha i Series Servo Amplifier