0544

Dead Zone Compensation Parameter Overflow

Fanuc · Alpha i Series Servo Amplifier

¿Qué significa 0544 ?

This invalid parameter setting alarm indicates that the internal calculation value of a parameter related to dead zone compensation has overflowed. This typically happens when the compensation setting is too high, leading to mathematical limits being exceeded.

Causas comunes

  • Dead zone compensation parameter calculation has overflowed.
  • System unable to effectively compensate for nonlinearities.
  • Parameter for dead zone estimation (P04-12) is too aggressive.
  • Significant backlash in gearboxes or couplings.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Decrease the setting of the parameter related to dead zone compensation to the extent that the invalid parameter setting alarm is no longer caused.