510

Positive Soft Stroke Limit Exceeded

Fanuc · Alpha i series AC Servo Motor

¿Qué significa 510 ?

The machine has exceeded its positive soft stroke limit, which is a software-defined limit. This indicates incorrect parameter settings for soft limits (No.142) or an invalid move command, potentially causing an unexpected stop.

Causas comunes

  • Appropriate values have not been specified for parameter No.142
  • An invalid move command has been specified

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check whether appropriate values have been specified for parameter No.142

  2. 2

    Check whether a valid move command is specified

  3. 3

    Move the tool in the opposite direction in jog mode, then perform a reset