405
Reference Position Return Error
Fanuc · Alpha i series AC Servo Motor
¿Qué significa 405 ?
Reference position return could not be executed correctly. This alarm can be triggered if parameter No. 032 (CMR) is configured with a value within the range of 4 to 96.
Causas comunes
- Reference position return procedure not completed successfully.
- Parameter No. 032 (CMR) is set to a value between 4 and 96.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Re-execute the reference position return procedure.
- 2
If parameter No. 032 (CMR) is set between 4 and 96, set bit 4 (N405) of parameter No. 001 to '1' to prevent this alarm.