Traduciendo...
400
Servo Motor Overheat (Estimated)
Fanuc · Alpha i series AC Servo Motor
¿Qué significa 400 ?
The servo motor has overheated, indicated by an estimated temperature exceeding safe operating limits. This suggests that the motor's operating conditions may be excessively severe, leading to thermal stress.
Causas comunes
- Motor operation conditions are too severe for the motor's thermal capacity (e.g., high duty cycle, excessive load).
- Ambient temperature around the motor is excessively high.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Evaluate the motor's duty cycle, load, and speed profile; reduce operating severity if possible.
- 2
Verify ambient temperature around the motor does not exceed specified limits.
- 3
If the alarm recurs after the motor has cooled, replace the motor or servo amplifier.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Fanuc Alpha i series AC Servo Motor