302

Serial Pulse Coder Communication Error (STBER)

Fanuc · Alpha i series AC Servo Motor

¿Qué significa 302 ?

A communication error (STBER) was detected for the serial pulse coder, suggesting a problem with data synchronization or framing during serial communication. This can be due to cable issues, faulty components, or noise.

Causas comunes

  • Discontinuity or damage in the serial pulse coder signal cable.
  • Defective serial pulse coder.
  • Defective servo amplifier module.
  • External electrical noise interfering with serial communication.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the continuity and integrity of the serial pulse coder signal cable.

  2. 2

    If the cable is verified as normal, replace the pulse coder or the servo amplifier module.

  3. 3

    Implement noise reduction measures as described in the 'Descriptions' chapter on noise.