300

Serial Pulse Coder Communication Error (DTER)

Fanuc · Alpha i series AC Servo Motor

¿Qué significa 300 ?

A communication error (DTER) was detected for the serial pulse coder. This can be caused by physical damage to the signal cable, a defective pulse coder or servo amplifier module, or external electrical noise interference.

Causas comunes

  • Discontinuity or damage in the serial pulse coder signal cable.
  • Defective serial pulse coder.
  • Defective servo amplifier module.
  • External electrical noise interfering with serial communication.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the continuity and integrity of the serial pulse coder signal cable.

  2. 2

    If the cable is verified as normal, replace the pulse coder or the servo amplifier module.

  3. 3

    Implement noise reduction measures as described in the 'Descriptions' chapter on noise.