093

Reference Position Not Established/Absolute PC Required

Fanuc · Alpha i series AC Servo Motor

¿Qué significa 093 ?

A first to third reference position return cannot be executed because the reference position has not yet been established, or an external setting was attempted without an Absolute pulse coder.

Causas comunes

  • The reference position has not been established.
  • Attempted external reference position setting without using an Absolute pulse coder.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Execute the procedure to set the reference position.

  2. 2

    For external reference position settings, verify that an Absolute pulse coder is correctly installed and configured.

Ver todos los códigos en este manual (60)