Over-voltage of Capacitor Module (ECM)
Fanuc · Alpha i Series AC Servo Motor and Spindle
¿Qué significa 7 ?
The voltage across the Capacitor Module of the ECM has exceeded its maximum safe operating voltage. This indicates an issue with charge control or excessive regenerative energy.
Causas comunes
- The voltage across the capacitor module exceeds its maximum rated voltage.
- External voltage surge applied to the capacitor module.
- Faulty capacitor module components (e.g., series elements).
- Incorrect operation of balancing circuits within the module.
- Overcharging of the capacitor bank.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Inspect the Capacitor Modules for signs of bulging or damage.
- 2
Check the ECM control module's charging and discharge control circuits.
- 3
Verify the operation of the regenerative discharge unit if connected.