Low-voltage of Control Power Supply (ECM)

Fanuc · Alpha i Series AC Servo Motor and Spindle

¿Qué significa 5 ?

The 24V control power supply voltage to the ECM has dropped below the acceptable threshold. This can lead to improper operation or shutdown of the ECM.

Causas comunes

  • The control power supply voltage (e.g., 24VDC) is below the minimum operational threshold.
  • Power supply unit failure or overload.
  • Loose wiring or poor connection to the control power input.
  • External short circuit on the control power lines.
  • Battery for control power is depleted or faulty.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Measure the 24V control power supply voltage at the input terminals to the ECM.

  2. 2

    Check the external 24V power supply unit for proper operation and load capacity.

  3. 3

    Inspect the wiring from the 24V power supply to the ECM for voltage drops or loose connections.