Traduciendo...
SP1227
Receive Error (CNC-Spindle, 30i)
Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters
¿Qué significa SP1227 ?
A receive error occurred in communication between the CNC and the serial spindle amplifier for Series 30i. This indicates an issue with the data reception at the CNC or potentially corrupted incoming data.
Causas comunes
- The spindle amplifier failed to correctly receive data from the CNC (30i).
- Corrupted data packets on the serial line.
- Intermittent connection issues on the serial communication path.
- A buffer overflow in the spindle amplifier's receive buffer.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Inspect the spindle amplifier's status register for specific receive error codes.
- 2
Verify the serial cable is securely connected at both the CNC and amplifier ends.
- 3
Measure the signal quality on the RXD line during communication.
- 4
Try communicating with a different serial device to isolate the issue.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Fanuc AC Spindle Motor Alpha i-Beta i Series Parameters