SP0226
Framing Error (CNC-Spindle, 15i)
Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters
¿Qué significa SP0226 ?
A framing error occurred in communication between the CNC and the serial spindle amplifier for Series 15i. This typically indicates a mismatch in communication protocol or timing parameters.
Causas comunes
- Data framing error in serial communication between CNC and spindle amplifier (15i).
- Incorrect start or stop bits configuration in serial communication settings.
- Data bits misalignment due to incorrect baud rate or bit timing.
- A faulty UART on either the CNC or the spindle amplifier.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Confirm serial communication parameters (baud rate, data bits, stop bits, parity) match on both ends.
- 2
Check the integrity of the serial data signal at the terminal block.
- 3
Inspect the serial connector for bent or broken pins.
- 4
Re-initialize the serial communication interface by cycling power to both the CNC and amplifier.
Datos técnicos verificados. Última actualización: March 2026