Traduciendo...
SP0010
Low Power Supply Input Voltage
Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters
¿Qué significa SP0010 ?
The input voltage to the low-power supply section of the spindle amplifier is below the acceptable threshold. This can cause unstable operation or prevent the amplifier from powering on.
Causas comunes
- Low input AC voltage to the spindle amplifier.
- Failure of the amplifier's internal low-voltage power supply circuitry.
- Loose connections on the low-voltage power input terminals.
- Faulty control transformer supplying the amplifier's auxiliary power.
- Overload on the low-voltage control circuits.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Measure the input AC voltage at the amplifier's L1, L2, L3 terminals.
- 2
Verify the output voltage of the amplifier's internal low-voltage rails (e.g., 24VDC).
- 3
Inspect low-voltage power connector for proper seating and corrosion.
- 4
Check the primary and secondary voltages of the control transformer.
- 5
Monitor the low-voltage supply during amplifier operation for dips.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Fanuc AC Spindle Motor Alpha i-Beta i Series Parameters