Traduciendo...
SP0002
Excessive Velocity Error
Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters
¿Qué significa SP0002 ?
The spindle motor's actual velocity deviated excessively from the commanded velocity. This can be caused by mechanical load, incorrect tuning, or encoder issues.
Causas comunes
- Insufficient torque from the spindle amplifier to meet commanded speed.
- Mechanical load changes exceeding amplifier capacity.
- Encoder feedback signal noise or loss of signal.
- Tuning parameters for velocity control (e.g., P1-02, P1-03) are suboptimal.
- Spindle encoder resolution mismatch with amplifier settings.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Inspect the encoder feedback cable for damage and ensure secure connections.
- 2
Verify that velocity feedback parameters (e.g., P1-02, P1-03) are appropriately tuned.
- 3
Measure the output voltage of the spindle amplifier during acceleration.
- 4
Check for any mechanical issues on the driven spindle or gearbox.
- 5
Confirm the encoder resolution matches the value configured in P1-06.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Fanuc AC Spindle Motor Alpha i-Beta i Series Parameters