849
Interruption of the SERCOS ring.
Bosch Rexroth · Motion Control
¿Qué significa 849 ?
The bit stream on the SERCOS ring has been interrupted, resulting in a loss of connection to the drives. This is a servo loop or drive fault, severely impacting real-time communication and control.
Causas comunes
- Interruption of the bit stream on the SERCOS ring.
- Lost connection to drives on the SERCOS ring.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check the integrity and connections of all glass fibers in the SERCOS ring.
- 2
Verify the operational status of all drives connected to the SERCOS ring.
- 3
Check all physical connections within the SERCOS ring.
- 4
Initiate a new SERCOS startup after rectifying physical issues.