Error when clearing diagn. class 1 error for %s-axis.

Bosch Rexroth · Motion Control

¿Qué significa 837 ?

The SERCOS command to reset a class 1 error cannot be set for the specified axis ('%s'). This is a servo loop or drive fault, indicating an inability to clear critical diagnostic errors, with no error recovery possible.

Causas comunes

  • Inability to set SERCOS command reset class 1 for the %s-axis.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the specific Class 1 diagnostic error reported by the Bosch Rexroth drive for the specified axis, as error 837 indicates an inability to clear a pre-existing Class 1 fault.

  2. 2

    Inspect all motor power cables and feedback cables for the affected axis for damage, proper seating, and secure connections at both the drive and motor ends.

  3. 3

    Measure the DC bus voltage and control supply voltage (e.g., 24VDC) at the drive input terminals for the affected axis, verifying they are within specified tolerances.

  4. 4

    Verify drive parameters related to the motor, feedback system, and control loop for the affected axis against the original machine documentation.