Traduciendo...
E3104
Plausibility error of safety parameters
Bosch Rexroth · IndraDrive Troubleshooting
¿Qué significa E3104 ?
This warning occurs in normal operation when safety technology is activated. It indicates a comparison showed that channel 1 and channel 2 are not operating with the same safety parameters. If a safety function is selected, this condition would trigger the F3140 Plausibility error of safety parameters error.
Causas comunes
- Channel 1 and channel 2 are not working with the same safety parameters.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Execute command P-0-3204 (Synchronize and store safety technology IDN command) to make channel 2 accept the parameters of channel 1.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Bosch Rexroth IndraDrive Troubleshooting