Traduciendo...
F8201

Safety command for basic initialization incorrect

Bosch Rexroth · IndraDrive MPx02

¿Qué significa F8201 ?

This fatal safety error indicates that the command received by the IndraDrive MPx02 for basic safety initialization is incorrect or invalid. This prevents the drive from establishing its fundamental safety functions, making it unable to operate safely and leading to a protective halt.

Causas comunes

  • Incorrect sequence or value of the safety initialization command from the master controller or safety PLC.
  • Mismatch between the expected safety protocol and the received command.
  • Communication error preventing the correct safety initialization command from reaching the IndraDrive MPx02.
  • Incorrect parameterization of the drive's basic safety settings.
  • Firmware incompatibility with the safety initialization procedure.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the exact sequence, timing, and value of the basic safety initialization command being sent by the master controller or safety PLC.

  2. 2

    Check safety parameters in the IndraDrive MPx02 related to basic safety functionality and ensure they are correctly set.

  3. 3

    Inspect the communication link between the master controller and the IndraDrive MPx02 for integrity.

  4. 4

    Ensure that the firmware version of the IndraDrive MPx02 is compatible with the safety configuration and initialization process.

  5. 5

    Refer to the IndraDrive MPx02 safety manual for the precise safety initialization procedure and required command structure.

Ver todos los códigos en este manual (99)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Bosch Rexroth IndraDrive MPx02