Traduciendo...
F7011

Safety rel. position limit val., exc. in pos. dir.

Bosch Rexroth · IndraDrive MPx02

¿Qué significa F7011 ?

This safety technology error indicates that the motor's actual position has exceeded the safety-related positive position limit value configured in the IndraDrive MPx02. This is a critical safety violation, implying the machine has moved beyond its safe upper boundary, requiring an immediate safety stop.

Causas comunes

  • Incorrectly set safety-related positive position limit (e.g., S-0-0193) in the IndraDrive MPx02.
  • Encoder counting error or offset, leading to incorrect actual position reporting.
  • Loss of control or unexpected motion command pushing the axis beyond the limit.
  • Mechanical overrun due to inertia or external forces.
  • Faulty safety limit switch or sensor that failed to activate or register.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Review and adjust the safety-related positive position limit parameter (e.g., S-0-0193 'Safety related position limit positive') in the IndraDrive MPx02, ensuring it is correct for the machine's physical limits.

  2. 2

    Verify the motor encoder for accurate position feedback. Check for mechanical slippage, loose couplings, or encoder damage.

  3. 3

    Inspect any external positive travel limit switches or sensors and their wiring for proper function and connection.

  4. 4

    Check the commanded motion profile and ensure that no trajectory attempts to exceed this limit.

  5. 5

    Perform a re-referencing or recalibration of the axis position, if applicable.

Ver todos los códigos en este manual (99)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Bosch Rexroth IndraDrive MPx02