F3152

Incorrect backup of safety technology data

Bosch Rexroth · IndraDrive MPx02

¿Qué significa F3152 ?

This non-fatal safety error indicates a problem during the backup or restoration of safety technology data on the IndraDrive MPx02. This means that the safety configuration or parameters may not be securely saved or restored, compromising the integrity of the safety system's settings.

Causas comunes

  • Attempted backup/restore with incompatible data versions (e.g., firmware mismatch).
  • Corruption of the backup file or the non-volatile memory in the drive.
  • Interruption during the backup or restore process (e.g., power loss).
  • Insufficient memory space for the backup operation.
  • Incorrect procedure followed for saving or loading safety parameters.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Ensure the correct procedure for backing up and restoring safety technology data is followed, as outlined in the IndraDrive MPx02 manual.

  2. 2

    Verify that the firmware version of the IndraDrive MPx02 is compatible with the safety data being backed up or restored.

  3. 3

    Check the integrity of the storage medium (e.g., SD card, MMC) if external storage is used for backup.

  4. 4

    Perform a memory check if possible, to rule out corruption of the internal non-volatile memory.

  5. 5

    Repeat the backup/restore process after a power cycle, ensuring no interruptions occur.

Ver todos los códigos en este manual (99)